note; these settings are once updated from my former settings whichever burned out my previous electric, besides disabling the EBS I lowered the current phase amps by a lot, maybe by furthermore much, so that's a what to might look at? Brushless Motor Controller for 48 Volt 3 KW Motor. Model: VEC200. Motor control mode: FOC. Driving method: Direct torque control.
Hi Jop, here are mein suggestions:
Decrease the maximal zeitabschnitt current duration and increase the maximum betrieb currents:
maximum phase current duration (s):
10.0 5.0
rated phasing contemporary:
80.0 250.0
Lower the battery currents to the rated setting:
battery drawn current boundary:
135.0 100.0
(that's still 7.2kW @72V)Delete each of the temperatures at which present limiting/motor protection occurs:
motor current limit cold (level 1):
120 110
motor current limit temperature (level 2):
130 120
maximum motor protection temperature:
150 140
80% of your forward set seems very fast for reverse:
backward speed ratio:
80 50 or even 25 press go?
Now you have which temperature protection enabled, it should not remain possible to overheat the motor.
Alan